Modification of the Design of the OMEGA-KSB Type Water Pump Impellers Used in Pumping Water at al-Sin Spring
Keywords:
Centrifugal pump, blade angle, CFD, tangential velocity, axial velocityAbstract
This research aims to improve the performance of the OMEGA-KSB 300-560A centrifugal water pump used in the drinking water pumping stations at Ain Al-Sin. This is achieved by modifying the impeller blade tilt angle, as the pump's efficiency has significantly decreased due to unstable operating conditions resulting from low suction water levels.
Theoretical calculations were performed to determine the design values for the impeller model in service, including tangential velocity, axial velocity, and impeller tilt angle. Reverse engineering was employed to select a range of proposed tilt angles, both within and outside the design range recommended by the German pump manufacturer. The impeller was modeled using SOLIDWORKS 2019 software, and CFD dynamic and mechanical analyses were performed for each model.
The results of this research show that a 20° tilt angle is suitable for the unstable operating conditions of the pump and achieves higher efficiency than the currently used 12.4°